(771) 213-3105Get an Estimate

Blog, Illustrative Walkthrough

What a typical row house mini split job looks like

An illustrative walkthrough, step by step, of one hot top-floor bedroom in a DC row house getting a single-zone mini split.

Last Updated:

The short answer

A single-zone job in a DC row house runs in four steps. A first call, a home visit where the room is measured and the panel checked, a written plan with the price, then an install of about a day once the DC permit is issued, ending with a pressure test, deep vacuum, startup and walkthrough.

Top-floor back bedroom of a DC brick row house with a new white mini-split head high on the plaster wall above a desk, a window unit gone from the sash

This is an illustrative walkthrough, not a specific customer’s job. It follows one typical case, a hot top-floor bedroom in a DC row house, through the four steps every Roomwise DC Mini Splits install follows, so you can see what happens and when.

The house and the problem

Picture a three-story brick row house with radiators and no ducts. The back bedroom on the top floor sits under a flat roof, and a window unit runs all night in July without ever getting the room comfortable.

The owner wants one thing: a bedroom that stays cool in summer and takes the edge off in winter, without losing the window. One room, one problem, which points to a single-zone system.

Step 1: The first call

The first call is short. We ask which room, how it’s used, how the house heats now, and whether the house is in a historic district.

That last question matters early. In a historic district, the permit includes a review of anything visible from the street, which can change where the outdoor unit goes. Outside one, the permit is simpler. We then book the home visit.

Step 2: The home visit

On the visit, we measure the room and work out four things: where the head goes, how the lines get out, where the water drains, and where the outdoor unit sits.

What gets decided in the room

  • Size. The head is sized from a heat-load calculation: the room’s dimensions, the roof above, the windows and their direction. Floor area alone would oversize it. The sizing guide explains why.
  • Head location. High on the back wall, an outside wall, so the lines and drain go straight through the brick behind it.
  • Drain. Through the same hole, falling by gravity to the yard. No pump needed.

What gets decided outside

  • Outdoor spot. A wall bracket on the rear wall below the bedroom window, since the yard is paved. The placement guide covers the clearances.
  • Line cover. A short painted cover down the rear wall to the unit.
  • Panel. We check the panel for room for a new circuit. In this example it has space, so no heavy-up is needed.

Step 3: The written plan and the permit

After the visit comes the written plan. It lists the equipment, the head and outdoor locations, the line route, the drain, the electrical work, and the price.

The price

For a job like this one, the price sits in Roomwise’s typical range for a standard single-zone install, $3,000 to $6,000. A historic review, a roof mount or a long run through finished rooms would move it higher. The cost guide shows how.

The permit

Once the owner signs, the DC Department of Buildings mechanical permit is filed. Every Roomwise install carries one. The permit guide covers what it involves.

Step 4: The install day

With the permit in hand, the install takes about a day. Floors are covered from the front door to the bedroom, and dust is contained at the wall.

  1. Mount the head plate on the back wall and core one hole through the brick behind it.
  2. Set the outdoor unit on its bracket and run the line set, drain and control wire between the two.
  3. Wire the circuit from the panel to an outdoor disconnect.
  4. Pressure test the lines with nitrogen to prove the flare joints hold.
  5. Pull a deep vacuum to clear air and moisture out of the lines.
  6. Release the refrigerant only after both tests pass, then start the system.

The walkthrough

At the end of the day, the owner gets a walkthrough: the remote, the modes, how to set a schedule, and how to slide out and wash the filters. The window unit comes out of the sash for good.

The rebate

Where the system qualifies, the DCSEU rebate can come off the invoice as an instant discount. Whether it does, and at what amount, depends on the equipment’s efficiency tier and on DCSEU’s current rules, which change during the program year.

For the current tiers and paperwork, read the rebates guide. For the steps of a larger job, see the installation process guide.

Questions about this post

Is this walkthrough based on a real customer's job?

No. It's an illustrative example built from the steps every Roomwise install follows. The house, the room and the choices in it are typical of DC row houses, not taken from one customer's home.

Do I need to be home on the install day?

It helps to be there at the start, to confirm the head location before any hole is drilled, and at the end, for the walkthrough of the remote, the modes and the filters. In between, you just need to leave access to the room, the panel and the outdoor spot.

What happens if the lines fail the pressure test?

The leak is found and fixed, often at a flare joint, and the test runs again. The lines then go through a deep vacuum. Refrigerant isn't released into them until they hold pressure and vacuum.

Want this answered for your house?

We look at the rooms, the walls and the panel, and put a plan with a price in writing.

Keep reading

Get an estimate for your house

Step 1 of 2

The house and the work